Fast FREE Shipping on orders over £35 *

Updated 5 November 2026

Fire exit signs work as a connected system. A clear notice above the final door is of limited help if a visitor cannot identify the route to that door.

Use the premises' fire risk assessment and escape arrangements to plan the scheme. Then check it from the position of someone unfamiliar with the building.

Follow the route in order

Start in an occupied room and trace the agreed route towards the final exit. Record junctions, changes of direction, stairs and other points where someone could become uncertain.

At each point, ask what the person can see next. Check doors in their normal open position and include displays, racking and stored materials.

For example, a meeting-room visitor may approach a corridor junction from the opposite direction to employees arriving from the workshop. One sign may not give both groups the information they need.

Choose arrows from the actual viewing position

Use an appropriate escape pictogram, with the direction needed at that location. Supporting text can help; a text-only notice should not replace the graphical escape sign.

Avoid ordering arrows from a floor plan alone. Check the complete sign arrangement from the reader's approach, especially at stairs and doorways. Seek competent advice where the direction could be ambiguous.

Keep the scheme consistent rather than mixing unrelated designs.

Plan visibility and illumination together

Check whether the sign remains legible under the conditions in which it is needed. Its size, location and illumination all matter.

Photoluminescent material needs exposure to light and fades over time after that light is removed. It is not a replacement for necessary emergency lighting. Do not assume every fire exit sign must glow in the dark.

The linked government offices-and-shops guidance is marked as applying to England. Use premises guidance and legal requirements appropriate to the building and its UK location.

Keep other fire messages accurate

A fire-door instruction concerns the door's operation. An exit sign identifies the escape route. A fire action notice explains the response to a fire. Check each against the arrangements it describes.

Signage also cannot replace evacuation assistance needed by occupants with mobility, sensory or other needs.

Record and revisit the scheme

Create a location list containing each sign, direction, viewing position and illumination arrangement. Check it after partitions, exits, room uses or occupancy change.

Remove obsolete directions only after confirming the revised scheme. Keep escape routes usable and explain the arrangements to employees.

Sources: GOV.UK: offices and shops fire risk assessment; HSE: L64 safety-sign guidance; GOV.UK: evacuation planning.

Leave a comment

Please note, comments need to be approved before they are published.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Latest Stories

This section doesn’t currently include any content. Add content to this section using the sidebar.